iMeter - Power & Environmental Monitoring

Contact us
Jacarta interSeptor Server Room Monitoring

interSeptor iMeter is an advanced environmental and power monitoring solution that has been designed to help IT personnel to analyse and reduce power usage in the data centre. The highly accurate data collected can be used to assess whether it is more economical to invest in newer, less power-hungry IT equipment rather than continuing to run existing equipment. The iMeter also allows users to compare power usage data with environmental conditions so power usage can be reduced in a safe and controlled manner.

3 principal components make up the interSeptor iMeter solution:

Jacarta Go-Probe Power and Environmental Sensors.

iMeter Master device with 8 sensor ports.

iMeter Slave device with 8 sensor ports.

interSeptor iMeter is an advanced environmental and power monitoring solution that has been designed to help IT personnel to;

Reduce power usage in the data centre.

Identify which racks are using the most power and are the most expensive to run.

Reduce the power consumption in data centre racks.

Assess whether it is more economical to invest in newer, less power-hungry IT equipment rather than continuing to run existing equipment.

Ascertain if temperature in the data centre be safely increased in order to help reduce air-conditioning and air handling costs.

Reduce Amps per U-space Ratio and running costs.

Analyse what effect running rack fans has on the AU ratio.

Reduce power usage safely without affecting network operations.

Receive alerts immediately about significant changes in power and environmental conditions that may otherwise have serious repercussions for network availability.

Implement an environmental and power monitoring solution without disruption to existing network infrastructure and without downtime.

intelliAmp

The remarkable intelliAmp Current Sensor has been designed to monitor the current draw of racks via 16A and 32A cables. The sensor contains a unique calibration mechanism to enable it to be positioned at the point where the optimal current reading can be obtained. The fact that the sensor simply clips to the cable means no network downtime is required to start monitoring your racks.

The intelliAmp Sensor can be used to track power usage within racks over time to ensure consumption can be gradually reduced as equipment is upgraded. The sensor can allow users to make power usage comparisons between racks and identify the most and least expensive racks to run. By building up a picture of power consumption across the data centre down to rack level, IT personnel can start to effectively manage power usage going forward and make savings where possible.

The flexibility of the intelliAmp Sensor means it can also be used to identify the effect on power consumption of running fans in racks, for instance, or the power implications of running the data centre at a higher temperature. This may help to reduce air conditioning power consumption but may also result in internal fans working harder and an increased power usage in this area. The key point is that the intelliAmp will help you to understand what is happening with the power across your data centre and manage it more efficiently.

intelliVolt

The intelliVolt voltage sensor simply connects into one of the iMeter sensor ports and plugs into a mains outlet. Voltage is monitored between 0 and 265v. High and Low threshold settings can be user configured on the iMeter to ensure alarm notification during over or under voltage conditions.

Temperature/Humidity

High and low warning and critical temperature and humidity thresholds can be configured in the iMeter to ensure alarms are raised when room or rack conditions are abnormal. The hysteresis configuration facility ensures that alarms are not continually triggered when levels are ‘floating’ around the configured thresholds.

Water Leak

The interSeptor water leak sensor is supplied with 3m or 18m of leak detection cable. The cable can be run under air conditioning units, in ceiling voids, under raised floors, under pipes, and around room perimeters to provide a comprehensive, easy-to-install, leak detection facility.

Smoke

The unique sensor connectivity design of the interSeptor facilitates installation and monitoring of the smoke detector, especially on ceilings. The cable connection need only be run from the temperature/humidity sensor which will typically already be installed at an elevated level.

Security

The security sensor option is a magnetic reed contact sensor, ideal for monitoring rack or room door access.

Power

The power sensor will detect the presence or otherwise of utility power.

Universal

The Universal sensor is an interface cable that can be connected to any device offering an open or closed or high/low output. interSeptor can monitor this output for changes in state and alarm accordingly. The Universal sensor can be connected to equipment such as generators, air conditioning units, printers, UPS, security systems, fire alarm systems, etc.

iMeter Datasheet